1. A flexible gas connector passing through a wall or cabinet partition is a concern because:
- AThe connector's length will change with temperature
- BThe connector will restrict gas flow at the bend
- CFlexible connectors may never be used indoors
- Connectors are not rated to pass through partitions
Why D is correct
Why this is correct: The governing concept is that flexible gas appliance connectors (corrugated brass or stainless steel tubing) are listed for specific uses. Their listing typically restricts them to a visible, accessible, and short run (usually 3 or 6 feet) between a rigid gas pipe and an appliance. They are not rated to pass through walls, floors, ceilings, or cabinet partitions because this concealed run exposes them to potential abrasion, puncture, and damage that cannot be seen or monitored. Why the other choices are wrong: 'The connector's length will change with temperature' is not the primary safety concern for a pass-through. 'The connector will restrict gas flow at the bend' is incorrect; flexible connectors are designed to bend without significant flow restriction. 'Flexible connectors may never be used indoors' is false; they are commonly and appropriately used indoors for appliance connections. Exam tip: Flexible gas connectors must be accessible and visible. Through a wall = defect.