Water Heaters & TPR Discharge
5:39 · Inspect TPR valves and discharge piping, combustion air, venting and seismic strapping.
Read the full written lessonThe rules, the worked example, the exam traps and the recap — free.
The water heater is the one appliance that can explode: the TPR valve and its discharge pipe are the safety system, and their rules are exact — full-size pipe, gravity flow, no threads on the end, terminating near the floor. Everything else is combustion, venting, and rust.
What this video covers
- TPR valve and discharge
- Combustion, venting, and location
- Tank condition and function
Key takeaways
- TPR discharge: full-size, gravity, one valve, ≤6 in of floor, unthreaded end
- Capped/missing discharge = top-priority finding
- Combustion air and draft: soot, roll-out, melt marks, backdraft tests
- Garage impact protection; pans above living space; state strapping
- Age + base rust + rumble = end-of-life budgeting
- Safety hierarchy: explosion, CO, restraint, leak