Drain, Waste & Vent Defects
5:43 ยท Explain trap seals, slope and venting, and why an S-trap fails where a P-trap works.
Read the full written lessonThe rules, the worked example, the exam traps and the recap โ free.
Drain-waste-vent systems run on physics: slope carries solids, traps hold a water seal against sewer gas, and vents protect that seal from siphonage. The S-trap โ self-siphoning by design โ is the classic defect that explains the whole system.
What this video covers
- Traps and their seal
- Venting
- Slope, materials, and evidence
Key takeaways
- P-trap seal 2โ4 in; S-traps prohibited (self-siphoning)
- Vents protect seals; gurgle and odor mark failures
- AAVs: listed, accessible, upright โ or a finding
- Attic/indoor vent terminations deliver sewer gas
- Slope ~1/4 in/ft โ both too little and too much fail
- Material stories: cast iron, clay roots, flex traps