Attic Ventilation & Net Free Area

5:40 · Balance intake and exhaust, compute the 1/150–1/300 ratios, and spot short-circuited venting.

Read the full written lessonThe rules, the worked example, the exam traps and the recap — free.

Attic ventilation runs on one ratio and one balance: 1/150 of the attic area in net free vent area, split roughly half intake (soffits) and half exhaust (ridge/upper), with air actually able to travel between them. Get the flow wrong and the house grows ice dams, cooked shingles, and wet sheathing.

What this video covers

  1. The ratio and the balance
  2. Flow-path failures
  3. Reading the symptoms

Key takeaways

  • 1/150 net free area base; balanced intake/exhaust
  • 1/300 only with vapor-retarder and balance conditions
  • Baffles keep soffit intake alive
  • Gable+ridge and attic-dumping ducts break the system
  • Symptoms: frost, staining, mold, ice dams, cooked shingles
  • Condition evidence outranks vent arithmetic